1. Home

Replacing a Water Heater Thermocouple or Flame Sensor

By

3 of 8

Disconnect Gas Control Valve Connections
Replacing a Water Heater Thermocouple or Flame Sensor

Disconnect pilot, main burner, thermocouple and Piezo igniter connections

© 2010 Home-Cost.com

Disconnecting the connections to the gas control valve is the first step in either the standing pilot or electronic ignition type of water heater.
  • Shut off the gas supply to the water heater and turn the gas control valve / thermostat to the "OFF" position.
  • Turn the temperature dial on the gas control valve / thermostat to its lowest setting.
  • Remove the cover panel exposing the burner assembly (standing pilot) or burner manifold cover plate (electronic ignition).
  • Using an adjustable wrench or appropriate sized open end wrench, loosen and remove the thermocouple connection, the main burner supply tube and the pilot supply tube from the control valve.
  • If this is an electronic ignition, remove the wire to the Piezo igniter.
If you have an electronic ignition water heater proceed to the next step #4. If you have an older style standing pilot water heater proceed to step #7.

Promotional Feature: View this video series to learn how to take good care of your house.